Weil-McLain · Heat pump
HP Low pressure in cooling, 3 times in an hour
What the control is telling you
In cooling, low side pressure (Pe) dropped under 87 psi three times within one hour.
Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)
Likely causes
- The manual sends you to the H6 checks for this code
Test and repair steps
- The manual points to the H6 checks for this code. Do those first.
Models that show this code
3 models in Weil-McLain ECO HP
Other codes on the same units
- HA Water outlet temperature sensor (Tw_out) fault
- HE Communication fault with Ta / room thermostat transfer board
- HF Outdoor unit EEPROM fault
- HH H6 fan fault 10 times in 120 minutes
- Hb PP three times and Tw_out under 44.6 F
- PP Tw_out - Tw_in reading not normal
- Pb Anti-freeze mode
- Pd Outdoor coil (T3) temperature too high
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.36. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.