Rheem · Furnace

AF Airflow readout (pushbutton status menu)

Menu / mode display R96V/96MDV

What the display is showing

Shows the blower's current target CFM, 100 to 9999, split over two displays: 1251 CFM appears as 12 then 51; 745 as 7 then 45.

Applies to: (-)96VA040-115 (R96V / U96V) and (-)(-)96MDV040-115 two-stage variable-speed communicating furnaces

What to do

  1. Step the pushbutton (under 2 s per press) until AF shows, then read the two number groups.

Settings for these units

Models that show this code

1 model in R96V/96MDV

96MDV115D50A

Other codes on the same units

  • 68 No blower communication (NO BLWR COMM)
  • 82 Supply air sensor fault (SA SENSOR FLT)
  • 84 Outdoor air sensor fault
  • d1 No shared data (NO SHARED DATA)
  • d6 Blower HP conflict (BLWR HP CNFLCT)
  • C Cooling or heat-pump heat (compressor call)
  • F Continuous fan on
  • FL Fault history (pushbutton status menu)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem (-)96V / (-)(-)96MDV Installation Instructions 92-24161-124-08, 15 Pushbutton (S8) p.95-96. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.