Rheem · Furnace

FL Fault history (pushbutton status menu)

Menu / mode display R96V/96MDV

What the display is showing

First category of the pushbutton status menu: up to six stored faults from the last 168 powered hours play back newest first. The right digit flashes its top and bottom bars before and after the list.

Applies to: (-)96VA040-115 (R96V / U96V) and (-)(-)96MDV040-115 two-stage variable-speed communicating furnaces

What to do

  1. Press the pushbutton for under 2 seconds; FL shows, then the stored codes one after another.
  2. Hold the button 5 seconds or more while FL is active to wipe the history (bars flash three times to confirm).
  3. Press again (under 2 s) to move to the next category; the menu closes after 60 seconds without a press.

Settings for these units

Models that show this code

1 model in R96V/96MDV

96MDV115D50A

Other codes on the same units

  • d1 No shared data (NO SHARED DATA)
  • d6 Blower HP conflict (BLWR HP CNFLCT)
  • AF Airflow readout (pushbutton status menu)
  • C Cooling or heat-pump heat (compressor call)
  • F Continuous fan on
  • Fr Fire rate readout (pushbutton status menu)
  • H Gas heat on
  • HP Heat-pump heat running (dual fuel)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem (-)96V / (-)(-)96MDV Installation Instructions 92-24161-124-08, 15 Pushbutton (S8) p.95-96. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.