Daikin water heater error codes
27 codes (26 faults, 1 normal display and menu code).
| Code | Meaning | Severity / type |
|---|---|---|
| 42 | Connector X3A disconnected (cascade) | High |
| 80 | Thermistor connector X17A disconnected (cascade) | Medium |
| 81 | Thermistor connector X18A disconnected (cascade) | Medium |
| A6 | Water not flowing in cascade unit | High |
| E3 | E3 subcode 01: cascade unit HPS connector unplugged | Medium |
| E4 | E4 subcode 02: heat source unit low refrigerant or stop valve closed | High |
| E9 | E9 subcode 01: cascade unit X23A valve coil connector unplugged | Medium |
| F3 | F3 subcode 01: cascade unit low refrigerant | High |
| H9 | H9 subcode 02: heat source X18A thermistor disconnected | Medium |
| J3 | J3 subcodes 16 to 19: cascade unit X29A thermistor disconnected | Medium |
| J5 | J5 subcode 03: heat source X30A thermistor disconnected | Medium |
| J6 | J6 subcode 02 | Medium |
| J7 | J7 subcodes 13 and 14: cascade unit X30A thermistor disconnected | Medium |
| J8 | J8 subcode 02 | Medium |
| J9 | J9 subcode 02 | Medium |
| P1 | Power supply voltage imbalance | High |
| U1 | Power wiring reverse phase or no power | Critical |
| U2 | Power supply voltage error, imbalance or phase loss | Critical |
| EC | Low tank water temperature | Normal status |
| HJ | Flow rate cannot be adjusted (cascade) | Medium |
| JA | High pressure sensor connector X32A disconnected | High |
| JC | Low pressure sensor connector X31A disconnected | High |
| LC | Inverter communication connectors disconnected | High |
| UC | UC: duplicate cascade unit address | High |
| UE | Transmission to tank control board not established | High |
| UF | Incorrect water piping connection | Medium |
| UJ | Active filter error | High |
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.