Daikin · Water heater

UE Transmission to tank control board not established

High severity Mega-Q

What the control is telling you

Controller kit: transmission between the cascade unit and the tank control board is not established. Also the cascade central address has not been set.

Applies to: Controller kit

Likely causes

  • Wiring between cascade unit and tank control board faulty
  • Cascade central address not set

Test and repair steps

  1. Check the wiring between the cascade unit and the tank control board per the transmission wiring section and correct any problems.
  2. Set the cascade central address per the cascade unit settings section.

Other codes on the same units

  • EC Low tank water temperature
  • HJ Flow rate cannot be adjusted (cascade)
  • JA High pressure sensor connector X32A disconnected
  • JC Low pressure sensor connector X31A disconnected
  • LC Inverter communication connectors disconnected
  • UC UC: duplicate cascade unit address
  • UF Incorrect water piping connection
  • UJ Active filter error

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin Mega-Q installation manual, p. 50. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.