Bosch · Boiler · Domestic hot water

Tank priority (ZBR with DHW tank)

Greenstar 3A

What happens, in order

  1. DHW tank call comes in while heating is running
  2. Default is DHW priority tank heats to setpoint first, then boiler goes back to space heating
  3. Space heating may pause during this and rooms can cool
  4. Pressing the ECO button switches to alternating operation, where the boiler swaps between heating and DHW
  5. Tank loading pump runs during DHW mode

Applies to: ZBR heating boiler with DHW tank

Models

ZBR 21-3AZBR 42-3A

More Bosch boiler sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Bosch Greenstar 6721853955 (2025-11) and 6721853953 (2025-11), Heatronic service functions and operation sections. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.