Selecting condensate disposal method

CRCC

What is going on

Condensate is acidic, about pH 3 to 4. Follow local code.

Check in this order

  1. Option 1 drain directly from the unit to a drain.
  2. Option 2 drain to a neutralizer, then to a regular drain.
  3. Option 3 drain to a laundry tub. The unit bottom must be above the tub rim and the line must slope down.
  4. Option 4 use a condensate pump to a laundry tub when the tub is far away or the unit sits below the tub rim.
  5. Check neutralizer lime stone every few months in the first year and replace it when depleted.

Applies to: CR and CC series water heaters

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR/CC installation manual, p. 19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.