Daikin · Water heater troubleshooting
Remove the compressor shipping plate
What is going on
A shipping plate over the compressor leg protects the unit in transit. It must come off before operation.
Likely causes
- Abnormal vibration or noise if the plate stays on during operation.
Check in this order
- Locate the shipping plate over the compressor leg.
- Remove the shipping plates.
- Retighten the compressor fixing bolts to 9.1 ft·lbf (12.3 N·m).
Applies to: Heat source unit
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin Mega-Q installation manual, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.