Daikin · Water heater troubleshooting

Remove the compressor shipping plate

Mega-Q

What is going on

A shipping plate over the compressor leg protects the unit in transit. It must come off before operation.

Likely causes

  • Abnormal vibration or noise if the plate stays on during operation.

Check in this order

  1. Locate the shipping plate over the compressor leg.
  2. Remove the shipping plates.
  3. Retighten the compressor fixing bolts to 9.1 ft·lbf (12.3 N·m).

Applies to: Heat source unit

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin Mega-Q installation manual, p. 10. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.