Choose a safe installation location

Mega-Q

What is going on

Pick a site that is flat, strong enough for the unit weight, and clear of flammable gas, noise problems and strong wind. Service space must also be kept.

Likely causes

  • Wind blowing straight into the air inlet or outlet can hinder operation.
  • Operating sound and airflow can disturb neighbours.
  • Electrical noise from the unit can interfere with AM radio and stereo equipment.

Check in this order

  1. Confirm there is no danger of flammable gas leaking near the site.
  2. Confirm the ground is level and can carry the weight and vibration of the unit.
  3. Confirm the refrigerant and water piping runs stay within the allowable piping limits.
  4. If wind hits the air inlet or outlet, install a wind barrier. If a snow hood is used at the outlet, face it away from the winter wind.
  5. Keep enough ventilation and service space for maintenance and inspection.
  6. Keep the remote controller and power and transmission wiring at least 10 ft. (3 m) from stereo equipment, PCs and similar equipment. Run power and transmission wiring in conduit and ground the conduit, especially where radio reception is weak.

Applies to: Heat source unit and cascade unit

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin Mega-Q installation manual, p. 9. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.