Release air from cascade unit water piping
What is going on
Purge air from the water side of the cascade unit before test operation.
Likely causes
- Air trapped in the circulating or hot water piping
Check in this order
- Open the lower front panel of the cascade unit.
- Open the gate valves on the circulating and hot water piping between the cascade and the storage tank so water can flow through the unit.
- Open both air release valves until only water comes out of the hose, then close the valves.
- Close the front panel when finished.
Applies to: Cascade unit water side
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Mega-Q installation manual, p. 41. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.