Daikin · Water heater troubleshooting

Protecting the storage tank during defrost and anti-freeze operation

Mega-Q

What is going on

Low-temperature hot water can flow back to the storage tank while the heat source is defrosting or running anti-freeze operation.

Likely causes

  • Low-temperature water from the generation system during defrost or anti-freeze operation.

Check in this order

  1. Install a three-way valve circuit between the hot water storage tank and the generation system.
  2. Connect the three-way valve operation circuit to the unit as described in the transmission wiring section (7-3).

Applies to: Hot water storage tank connection

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin Mega-Q installation manual, p. 21. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.