Daikin · Water heater troubleshooting

Power supply circuit requirements

Mega-Q

What is going on

Rated supply for the unit is 208/230 V. The power circuit needs a main switch and a slow-blow fuse on each phase. Copper conductors only, insulated power cord, cable sized to local and national code.

Check in this order

  1. Confirm supply is 208/230 V before connecting.
  2. Provide a dedicated circuit with a main switch and a slow-blow fuse on each phase.
  3. If using a residual current breaker, use a high-speed type (0.1 s or less) rated 100 mA.
  4. Use copper conductors and insulated power cord only.
  5. Size the power cable per local and national regulations.

Applies to: Mega-Q heat source and cascade units

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin Mega-Q installation manual, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.