Install water temperature sensors inside the storage tank

Mega-Q

What is going on

Sensors go in sockets inside the tank, with a storage box to keep them dry. Sensors are precision parts; replace any that have been dropped or shocked.

Check in this order

  1. Wrap sealing tape around the thread of each water temperature sensor.
  2. Screw the sensor into its socket.
  3. Fasten the storage box with four M4 x 8 screws.
  4. Fasten the storage box cover with two M4 x 8 self-tapping screws.
  5. Keep the storage box dry; water reaching the sensor inside it can cause electric shock or fire.

Applies to: Mega-Q water temperature sensors 1 to 3 (upper, middle, lower)

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Mega-Q installation manual, p. 52. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.