Daikin · Water heater troubleshooting
Handle, lift and unpack the unit
What is going on
The unit is fragile and must stay upright. Use proper lifting gear and protectors.
Likely causes
- Compressor damage if the unit is tilted.
- Belt damage from sharp edges without protectors.
Check in this order
- Choose the route into the site before moving the unit.
- Keep the unit upright at all times.
- Lift with a crane and two belts at least 27 ft. (8 m) long, using protectors on the belts.
- Use belt slings no wider than 3/4 in. (20 mm) that can carry the unit weight.
- Use a forklift only while the unit stays on its pallet.
- Remove the packing, then remove the 4 bolts that hold the unit to the pallet.
- Do not touch the air inlet or aluminium fins with bare hands.
- Dispose of packing and plastic bags safely so children cannot reach them.
Applies to: Heat source unit and cascade unit
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin Mega-Q installation manual, p. 8-9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.