Navien · Water heater troubleshooting

Electrical wiring, grounding and surge protection

CRCC

What is going on

Wiring and grounding rules for connecting the heater to power.

Check in this order

  1. Follow the local electrical code; if none applies, follow NFPA 70 (US) or CSA C22.1 (Canada).
  2. Confirm the receptacle is properly grounded.
  3. If hardwiring, remove the factory plug and do not bond the ground wire to gas or water piping, since plastic pipe or dielectric unions can isolate the heater electrically.
  4. Use a surge protector if possible.
  5. Label all wires before disconnecting them during service.
  6. Check proper operation after any control service.

Applies to: Electrical connection of CR and CC water heaters

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: CR-CC installation manual, p. 32. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.