Electrical wiring general rules
What is going on
Field wiring must be done by a licensed electrician to local and national code. Use a dedicated circuit, do not install a phase-advancing capacitor, and never remove a thermistor or sensor while wiring.
Check in this order
- Use a dedicated power circuit; never share it with another appliance.
- Do not install a phase-advancing capacitor (inverter risk).
- Turn off all power before wiring work.
- Ground the unit per local code. Do not ground to gas pipes, sewage pipes, lightning rods or telephone grounds.
- Do not run the unit until refrigerant piping is finished.
- Do not remove any thermistor or sensor when connecting power or transmission wiring.
Applies to: Mega-Q tank control board and whole system
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Mega-Q installation manual, p. 55. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.