Navien · Water heater troubleshooting

Clearing a blocked condensate siphon

CRCC

What is going on

When debris blocks the siphon, condensate cannot drain. The unit then shows an error and shuts down.

Likely causes

  • Debris blocking the condensate siphon
  • Condensate cannot be released from the unit

Check in this order

  1. Set a bucket under the siphon to catch residual water.
  2. Twist and remove the siphon cap, drain the siphon, clean it out, then reinsert the cap and retaining clip.
  3. Open the fill valve and let water fill the siphon to the top, then close the valve.
  4. Open a hot water faucet.
  5. Check the open end of the condensate drain line. If flue gases are coming out, stop the unit immediately and call Navien for instructions.

Applies to: CR and CC series water heaters

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR/CC installation manual, p. 20. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.