Navien · Water heater troubleshooting
Change the master unit
What is going on
Changing the master is recommended over the alternative process.
Check in this order
- Power off all units.
- Choose a new master and set its DIP SW2 1st switch to ON; set the others to OFF.
- Repeat the cascade communication set-up.
- Confirm all FND displays show the setting temperature.
Applies to: Cascade systems
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: CR-CC installation manual, p. 35-38. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.