Navien · Water heater troubleshooting
Cascade plumbing and cable connection
What is going on
Connect up to 98 units in cascade with Navien Multi-Link cables.
Check in this order
- Size the trunk line properly for the application and connect the units to the hot and cold trunk lines.
- Choose one unit as the master; the recommended location is the center of the group.
- With power off, connect the cascade communication cable to the CN9 port on the PCB, using the PCB connecting adapter and wire connecting adapters.
- Connect slave units in a chain from the master.
Applies to: Cascade installations of CR and CC water heaters
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: CR-CC installation manual, p. 35. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.