Navien · Tankless water heater troubleshooting
Wall mounting
What is going on
The unit hangs on an upper bracket on the wall.
Check in this order
- Fasten the upper mounting bracket to studs, level, and make sure the wall can hold the unit's weight.
- If framing is non-standard or the surface is uneven, fasten 3/4 in plywood to the studs and mount the bracket to the plywood.
- Note that the supplied bracket leaves a 5/8 in gap behind the unit.
- Hang the unit on the bracket by engaging the hanger brackets on the back top corners with the bracket tabs.
Applies to: All CR and CC installations
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR/CC installation manual, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.