Navien · Tankless water heater troubleshooting

Direct vent (sealed combustion) requirements

CR/CC

What is going on

Navien units ship set up for direct vent, drawing combustion air from outside. Both exhaust and intake use round 3-inch pipe. Intake may be ABS, PVC, galvanized steel or corrugated aluminum. Do not crimp or damage corrugated intake.

Check in this order

  1. Confirm 3-inch round exhaust and 3-inch round air intake.
  2. Seal exhaust and intake airtight from unit collar to terminator.
  3. If using corrugated intake, check for crimps or damage.

Applies to: All CR/CC models in direct vent

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR-CC installation manual, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.