Navien · Tankless water heater troubleshooting
Direct vent (sealed combustion) requirements
What is going on
Navien units ship set up for direct vent, drawing combustion air from outside. Both exhaust and intake use round 3-inch pipe. Intake may be ABS, PVC, galvanized steel or corrugated aluminum. Do not crimp or damage corrugated intake.
Check in this order
- Confirm 3-inch round exhaust and 3-inch round air intake.
- Seal exhaust and intake airtight from unit collar to terminator.
- If using corrugated intake, check for crimps or damage.
Applies to: All CR/CC models in direct vent
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR-CC installation manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.