Navien · Tankless water heater troubleshooting

Typical vent configurations (options 1, 2 and 4)

CR/CC

What is going on

Option 1 is a 3-inch two-pipe side wall vent. Option 2 is non-concentric side wall venting with the air intake drawn from a different location at least 12 inches from the termination. Option 4 is a 3-inch two-pipe vertical termination. These are examples and not the only allowed layouts.

Check in this order

  1. For side wall venting, keep the air intake run as short as practical.
  2. Keep at least 12 inches from the terminator to any obstruction (above, below, left or right) on vertical termination.
  3. Follow the diagrams for interior and exterior views when laying out the system.

Applies to: Two-pipe venting

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR-CC installation manual, p. 29-31. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.