Navien · Tankless water heater troubleshooting
Typical vent configurations (options 1, 2 and 4)
What is going on
Option 1 is a 3-inch two-pipe side wall vent. Option 2 is non-concentric side wall venting with the air intake drawn from a different location at least 12 inches from the termination. Option 4 is a 3-inch two-pipe vertical termination. These are examples and not the only allowed layouts.
Check in this order
- For side wall venting, keep the air intake run as short as practical.
- Keep at least 12 inches from the terminator to any obstruction (above, below, left or right) on vertical termination.
- Follow the diagrams for interior and exterior views when laying out the system.
Applies to: Two-pipe venting
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR-CC installation manual, p. 29-31. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.