Navien · Tankless water heater troubleshooting

Space heating water piping

CRCC

What is going on

Space heating and potable water share this unit, so piping rules apply.

Check in this order

  1. Use components rated for potable water in the space heating piping.
  2. Do not add boiler treatment chemicals to the potable water used for space heating.
  3. Do not connect the unit to any heating system previously used with a non-potable water heater.
  4. Install a mixing valve where space heating needs hotter water than the other uses, and follow the piping diagram in the instructions.

Applies to: Space heating installations

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR/CC installation manual, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.