Navien · Tankless water heater troubleshooting
Selecting the install location
What is going on
Location affects performance and service access. The contractor should weigh these factors.
Check in this order
- Place the unit near a drain for condensate and possible leaks.
- Keep the unit close to the city water entry and the gas entry if practical.
- Place it near the main fixtures to shorten water runs. Use an A model and a recirculation line if the runs are long.
- Plan the vent route to avoid windows, doors, air intakes, gas meters and neighbor openings.
- Do not install in bathrooms, bedrooms or normally closed occupied rooms.
- Keep the air supply clean. Avoid dust, debris and chemical agents such as hair spray, spray detergent and chlorine.
- Leave service access for the water filter, air filter and condensate trap.
- Keep combustibles and hanging laundry clear of the unit and its vent.
- Do not install where gasoline or flammables are stored.
- For commercial use, avoid greasy fumes and large amounts of steam.
Applies to: Installation location
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR/CC installation manual, p. 14-15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.