Navien · Tankless water heater troubleshooting

Non-direct vent: freeze risk and make-up air

CR/CC

What is going on

Non-direct vent can backdraft cold outdoor air through the heat exchanger during negative building pressure, which can freeze it. Damage from insufficient make-up air is not covered under warranty. Direct vent is strongly recommended in cold climates.

Likely causes

  • Negative pressure in the building
  • Insufficient make-up air inside the home

Check in this order

  1. Use direct vent whenever possible.
  2. If non-direct vent is required, provide ample make-up air.
  3. For non-direct, insert the termination end cap (supplied) into the air intake collar. Do not glue it so it can be removed for cleaning.
  4. Check the building for negative pressure before commissioning.

Applies to: Non-direct vent installations

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR-CC installation manual, p. 25-26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.