Navien · Tankless water heater troubleshooting
Non-direct vent: freeze risk and make-up air
What is going on
Non-direct vent can backdraft cold outdoor air through the heat exchanger during negative building pressure, which can freeze it. Damage from insufficient make-up air is not covered under warranty. Direct vent is strongly recommended in cold climates.
Likely causes
- Negative pressure in the building
- Insufficient make-up air inside the home
Check in this order
- Use direct vent whenever possible.
- If non-direct vent is required, provide ample make-up air.
- For non-direct, insert the termination end cap (supplied) into the air intake collar. Do not glue it so it can be removed for cleaning.
- Check the building for negative pressure before commissioning.
Applies to: Non-direct vent installations
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR-CC installation manual, p. 25-26. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.