Navien · Tankless water heater troubleshooting

Installation checklist: water supply

CR / CC

What is going on

Check the cold supply and hot outlet before leaving the site.

Check in this order

  1. Confirm water supply pressure is greater than 40 psi.
  2. Confirm shut-off valves are on the inlet and outlet for cleaning the cold inlet filter.
  3. Bleed air out of each fixture.
  4. Check that each fixture delivers hot water.
  5. Clean the cold inlet water filter.
  6. If a recirculation line is installed, insulate all hot water pipes and the recirculation return line.

Applies to: Installation checklist

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR-CC installation manual, p. 43. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.