Navien · Tankless water heater troubleshooting
Hot water turns cold - Navien NPE-2
What is going on
Hot water goes cold and stays cold. Navien NPE-A2 or NPE-S2. Flow, filter, code, gas. Check in that order. Burner needs at least 0.5 GPM to fire. Low flow is the easy miss. Low gas at high demand is the other one.
Likely causes
- Clogged inlet filter
- Flow below the 0.5 GPM minimum
- Error code
- Missing check valve on an external recirculation return
- Gas pressure dropping at high demand
Check in this order
- Clean the cold water inlet filter, isolate and drain first
- Open the tap fully, at least 0.5 GPM must flow to fire the unit
- Check the display for an error code and look it up
- With an external recirculation system, make sure a check valve is on the recirculation return line, or cold water backfeeds into the hot side
- Check gas pressure at max fire (3.5-10.5 in. WC NG, 8.0-13 in. WC LP) if it happens at high demand, gas work is for a licensed tech
- Try one fixture only to see whether it is a capacity issue
- Check for a crossover at mixing valves or single-handle faucets
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1 Solving Basic Problems, p.16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.