Navien · Tankless water heater troubleshooting

Hot water turns cold and stays cold

CR/CC

What is going on

Hot water runs at first and then stays cold.

Likely causes

  • Flow rate too low to keep the Model 35-1 running (as printed in the manual)
  • Recirculation line check valves missing or wrong (if a recirculation system is installed)
  • Gas supply valve not fully open
  • Cold water inlet filter dirty
  • Fixtures clogged with debris or obstructions
  • Cross plumbing between cold and hot lines

Check in this order

  1. Confirm the flow rate is enough to keep the unit running.
  2. If a recirculation system is installed, check that the recirculation line has the correct check valves.
  3. Confirm the gas supply valve is fully open.
  4. Clean the filter on the cold water inlet.
  5. Clean fixtures of debris and obstructions.
  6. Check for cross plumbing between cold and hot water lines.

Applies to: CR/CC series water heaters

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CR/CC installation manual, p. 59. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.