Navien · Tankless water heater troubleshooting
Hot water temperature fluctuating
What is going on
Outlet temperature goes up and down.
Likely causes
- Incoming cold water pressure too low (minimum 15 PSI)
- Cold water inlet filter dirty
- Gas line undersized
- Supply gas pressure too low
- Cross connection between cold and hot water lines
Check in this order
- Check that incoming cold water pressure is at least 15 PSI.
- Clean the filter on the cold water inlet.
- Confirm the gas line is sized correctly.
- Confirm supply gas pressure is adequate.
- Check for a cross connection between cold and hot water lines.
Applies to: CR/CC series water heaters
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR/CC installation manual, p. 59. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.