Navien · Tankless water heater troubleshooting
Hot water slow to reach fixtures - Navien NPE-2
What is going on
If you turn on a tap and wait forever for hot water on a Navien NPE-A2 or NPE-S2, the heater is probably fine. The wait comes from the pipe run, because the water sitting in the line has to be pushed out before hot water gets there. Recirculation fixes that by keeping hot water moving, but the unit has to be set up and the plumbing has to support it. Here is what to look at.
Likely causes
- No recirculation return line
- Recirculation mode not set
- 2-way valve on an A2 set to the wrong position
- External recirculation run too long for the built-in pump
Check in this order
- A2 models use Internal Recirculation (2-way valve set to INT) for faster delivery, or External Recirculation (valve set to EXT) with a return line from the farthest fixture
- S2 models need an external pump and return line (or NaviCirc valve)
- Set Menu > 1. Recirculation Settings to Always On, Intelligent, Weekly or HotButton, pick the one that fits the household
- Built-in pump limits on external recirculation: 100 ft equivalent of 1/2 in. copper or 500 ft of 3/4 in. copper, longer runs need an external pump
- Insulate the hot lines to hold the heat longer
- Explain to the homeowner what each mode costs in gas and electricity
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1, p.16; Navien NPE-A2/S2 Installation Manual, 3.4.2, p.27-29. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.