Navien · Tankless water heater troubleshooting
Electrical wiring, surge protection and power-failure freezing
What is going on
Follow the local electrical code, or NFPA 70 / CSA C22.1 where there is no local code. Freeze protection does not run during a power outage, so the heat exchanger can freeze. Damage from freezing is not covered by warranty.
Likely causes
- Power outage in cold weather
- Freeze protection disabled without power
Check in this order
- Verify the receptacle is properly grounded.
- Use a surge protector where power surges are a concern.
- Install an on/off switch between breaker and heater when wired direct.
- In cold areas with frequent outages, drain the unit completely if power will be off for an extended time.
- A battery backup may be used to keep hot water during outages.
- Label all wires before disconnecting for service.
- Check proper operation after any control service.
Applies to: All CR/CC models
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CR-CC installation manual, p. 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.