Gree · Heat pump troubleshooting
Weak cooling or heating - Gree ductless
What is going on
Unit runs but room temperature is not reached.
Likely causes
- Setpoint or fan speed too low
- Dirty filter
- Poor indoor/outdoor unit location
- Refrigerant leak
- 4-way valve fault (cold air in heating)
- Capillary/EEV restriction
- Service valve not fully open
Check in this order
- Check setpoint and set fan to high or medium.
- Clean the filter.
- Check installation clearances and shading of the outdoor unit.
- Compare supply air temperature and pressures with normal; low readings point to a leak or restriction.
- Open both service valves fully.
- Cold air in heating with good charge replace the 4-way valve.
Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.