What is going on

If your Gree ductless indoor unit shows no lights and makes no beep, or the breaker trips the moment power goes on, you are dealing with a power or wiring problem, not a refrigerant one. Start with the easy stuff like whether there is actually power at the outdoor unit and whether the remote works. A breaker that trips right away usually means a ground fault, so don't keep resetting it. Applies to Gree Sapphire, Livo GEN4, Vireo GEN3 and Multi21+ units.

Likely causes

  • No power, or a loose plug or supply connection
  • Interconnect wiring wrong or loose
  • Ground fault or damaged cord
  • Wrong breaker size
  • Remote battery or remote fault

Check in this order

  1. Confirm supply at the outdoor unit, if the lights stay off with good power, check the interconnect terminals against the wiring diagram
  2. If the breaker trips right away, check grounding and look for damaged insulation on the cord and internal wiring, and do not keep resetting it
  3. Make sure the breaker is the correct size for the unit, per the rating plate
  4. If the unit has power but the remote shows nothing, replace the batteries or the remote
  5. Power off at the disconnect before touching any terminals
  6. Call a licensed electrician or tech for line voltage faults

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.