Gree · Heat pump troubleshooting

Outdoor fan will not run - Gree ductless

What is going on

The outdoor fan on a Gree ductless system (Sapphire, Livo, Vireo or Multi21+) does not turn while the unit is calling. Shut off power at the disconnect and let the capacitors discharge before touching anything, since the outdoor unit carries line voltage. If you are not trained for live electrical measurements, call a qualified technician.

Likely causes

  • Loose fan wiring at the board
  • Fan capacitor out of range on AC fan motors
  • Supply voltage high or low
  • Fan motor failed

Check in this order

  1. Check fan wiring at the board with the power off.
  2. Test the fan capacitor against its nameplate value, after discharging it safely.
  3. Measure supply voltage at the unit; suggest a regulator if it is unstable.
  4. Check the fan blade spins freely by hand with power off.
  5. Replace the fan motor if it fails after the above checks.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.