Gree · Heat pump troubleshooting

Compressor will not run - Gree ductless

What is going on

Gree ductless, outdoor fan may spin but the compressor never starts. Sapphire, Livo, Vireo, Multi21+. Wiring, voltage, then windings. In that order.

Likely causes

  • Loose compressor wiring
  • Capacitor fault, where one is used
  • Supply voltage high or low
  • Burnt winding reading 0 ohm
  • Seized compressor

Check in this order

  1. Check compressor wiring against the diagram, power off.
  2. Measure supply voltage at the outdoor unit.
  3. Test the capacitor where used.
  4. Measure winding resistance. A short means replacing the compressor, which is a licensed refrigerant job.
  5. Seized compressor, replace it.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.