Gree · Heat pump troubleshooting
Noise or vibration - Gree ductless
What is going on
Clicks, gurgles or rattles from the indoor or outdoor unit. Gree Sapphire, Livo, Vireo and Multi21+. Many of the noises are normal and customers just have not heard them before. Sort normal from abnormal first.
Likely causes
- Plastic expanding at start and stop (normal)
- Refrigerant flow noise (normal)
- Loose parts or debris
- 4-way valve coil buzz
- Compressor not sitting on its mounts, or internal noise and overcharge
Check in this order
- Cracking or water-flow sounds at start and stop are normal and fade in a few minutes, tell the customer
- Remove debris, tighten screws and add damping where parts touch
- Replace a buzzing 4-way valve coil
- Check compressor feet and bolts, because a compressor off its mounts transmits vibration to the cabinet
- If noise is internal, check for overcharge, else replace the compressor
- Power off before opening panels, and use a licensed tech for refrigerant work
Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.