Gree · Heat pump troubleshooting

Water leaking from indoor unit - Gree ductless

What is going on

If water is dripping from the indoor unit or the line set on a Gree ductless system (Sapphire, Livo, Vireo or Multi21+), it is almost always a drain issue or loose insulation wrap, not a refrigerant leak. When the cold suction line is not wrapped tight at the indoor connection, it sweats and the water runs down the wall like a leak.

Likely causes

  • Drain line blocked
  • Drain line broken or cracked
  • Pipe insulation wrap loose at the indoor connection, so the line sweats

Check in this order

  1. Clear the drain line, and run water through the pan to confirm it flows out.
  2. Replace a cracked drain hose.
  3. Rewrap the indoor pipe connections tightly so there are no gaps.
  4. Check the unit is level or slightly pitched toward the drain side.
  5. Run the unit in cool mode for a while and watch for any remaining drips

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.