Daikin · Heat pump troubleshooting
Using the 4-pin connectors on communicating equipment
What is going on
Communicating indoor and outdoor units use a supplied 4-pin connector. Indoor units match R, C, 1 and 2 on the 4-pin to the indoor board. Outdoor units match 1 and 2 on the 4-pin to the outdoor board. The thermostat is labeled 1, 2, C and R, and wrong wiring gives a communication error or unrecognized equipment.
Likely causes
- 4-pin connector wired to the wrong board terminals
- Thermostat labels 1, 2, C, R not matched to the equipment
Check in this order
- Match R, C, 1 and 2 on the indoor 4-pin connector to the same terminals on the indoor board.
- Match 1 and 2 on the outdoor 4-pin connector to the outdoor board.
- Confirm the thermostat 1, 2, C and R wires land on the matching terminals.
Applies to: Communicating indoor and outdoor units
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin One Touch installation guide, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.