Adding an aux heat source in the Daikin One+ setup menu

P1P2S21

What is going on

The aux heat source is added in the Equipment Setup menu. Once added, Emergency heat mode also appears in the system mode menu. The aux heat can be set as the primary or secondary heat source. The heat pump is the default primary source.

Check in this order

  1. Open the Equipment Setup menu on the Daikin One+.
  2. Select Add equipment, then Aux heat source.
  3. Set Connection to aux1 or aux2 to match the wiring to the aux heater.
  4. Choose whether the aux heat is primary or secondary; heat pump is primary by default.
  5. Open the control to adjust the parameters.

Applies to: Daikin One+ thermostat on P1P2 or S21 systems

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Aux heater installation and setup instructions, p. 2. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.