Auxiliary output wiring
What is going on
The thermostat Aux outputs are dry contacts that close to switch on an auxiliary device. A 24VAC control signal must be routed through one of the Aux contacts. Aux terminals are chosen in the Daikin One installer wizard. Use a minimum of 18-gauge wire and keep the run under 125 feet.
Check in this order
- Wire the auxiliary device through an Aux 1 or Aux 2 dry contact (N.O. and Com).
- Route the 24VAC control signal through one of the Aux contacts.
- Use at least 18-gauge wire, no longer than 125 feet.
- Select the Aux terminal in the Daikin One installer wizard.
- Confirm the field device has its own line voltage supply through the relay.
Applies to: Auxiliary equipment on the One Touch thermostat
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin One Touch installation guide, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.