Aux relay wiring to a field device
What is going on
Wire an aux output so the thermostat closes a dry contact to start the field equipment.
Check in this order
- Use at least 18 AWG wire and keep the run to 125 ft or less.
- Pick an aux terminal pair (Aux 1 or Aux 2) and note it for the installer wizard.
- Wire the field device to the N.O. and Com of the SPST relay side, with line voltage on the field device side.
- Route the 24 VAC control signal through one of the aux contacts.
- Set the aux terminal in the Daikin One installer wizard.
- Check that the field device energizes when the aux output is called.
Applies to: Aux 1 / Aux 2 outputs on the Daikin One Touch thermostat
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin One Touch Smart Thermostat training module TRC-10, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.