Daikin · Heat pump troubleshooting

Unit does not operate

FTXM-WFTXM-V

What is going on

The unit does not start. Work through the power, unit type, outdoor temperature, remote diagnosis and remote address checks in order.

Likely causes

  • No or wrong supply voltage
  • Indoor unit type not compatible with outdoor unit
  • Outdoor temperature outside the operation limit
  • Remote controller addresses not set correctly

Check in this order

  1. Check the power supply and confirm the rated voltage is present.
  2. Confirm the indoor unit type is compatible with the outdoor unit.
  3. Check the outdoor temperature against the operation limit on the reference page (p. 176).
  4. Diagnose using the remote controller indication (see p. 96).
  5. Check that the remote controller and indoor unit addresses are set correctly (see p. 159).

Applies to: FTXM-W/V wall mounted inverter pair

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: SiUS042113EA service manual, p. 96. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.