Thermostat will not connect to internet or Wi-Fi during setup

Daikin One Touch

What is going on

The app requires a verified internet connection before any task can continue. A grey Wi-Fi icon means the system is not connected to Wi-Fi.

Likely causes

  • Thermostat is not connected to Wi-Fi (grey Wi-Fi icon).

Check in this order

  1. Tap "apply system profile" in the app.
  2. On the thermostat, go to the communication option in the 5-step commissioning process.
  3. Check the "use Wi-Fi" option.
  4. Select the network.
  5. Enter the password.
  6. Wait for "Daikin One Cloud" to show connected on the thermostat.
  7. Tap "Continue" in the app.

Applies to: Daikin One Touch thermostat

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin One Touch Smart Thermostat Training Module TRC-10, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.