Trane · Heat pump troubleshooting

Thermostat placement

XR103

What is going on

Choose a location that gives an accurate room temperature reading.

Check in this order

  1. Mount on an interior wall in a central spot with good air circulation.
  2. Keep it away from lamps, sunlight, fireplaces and other radiant heat.
  3. Keep it away from windows, doors to the outside, outside walls and alcoves with poor airflow.
  4. Keep it out of direct air from supply registers or ceiling fans.
  5. Do not mount it on a wall with hot or cold water pipes or ducts.
  6. Figure 1 on page 4 shows the optimum zone and correct placement.

Applies to: XR103 wall mounting

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR103 installation and user guide 18-HD55D1-1C-EN, p. 3. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.