Compressor lockout (flashing flame and snowflake icons)

XR103TCONT103

What is going on

When the compressor lockout feature is on, the thermostat waits before starting the compressor after a power loss or after switching between heating and cooling. During this wait the flame and snowflake icons flash for about five minutes.

Likely causes

  • Compressor lockout (CL ON) is active after a power interruption
  • Switching between cooling and heating too quickly

Check in this order

  1. Wait about five minutes for the timed delay to finish.
  2. If the icons keep flashing after the delay, check the CL setting in the configuration menu.
  3. Some newer compressors have their own delay. Ask the compressor manufacturer whether lockout is already built in before leaving CL on.

Applies to: XR103 / TCONT103 heat pump thermostat in lockout

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane TCONT103 installation and user guide, p. 8-9. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.