Auxiliary heat lockout by outdoor temperature
What is going on
Auxiliary heat lockout is set with an outdoor temperature. No installed auxiliary heat stage turns on during heating above that temperature. During defrost this setting is ignored and the Defrost Heater Balance Point thresholds are used instead. Requires the outdoor sensor.
Check in this order
- Confirm the outdoor sensor is installed and enabled.
- Set the auxiliary heat lockout outdoor temperature in the installer setup.
- Check that no auxiliary heat stage runs above the set temperature during heating.
Applies to: Heat pump with auxiliary heat and TCONT402AN32DA
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: 18-HD29D3-4 installer's guide, p. 17. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.