Trane · Heat pump troubleshooting
Thermostat base mounting
What is going on
Wall mounting sequence for the XR103 base.
Check in this order
- Turn OFF all power to the heating and cooling equipment.
- If replacing a thermostat, record the color and terminal marking of each wire before disconnecting.
- Remove the old thermostat and keep the wires from falling back into the wall.
- Pull the cover off the thermostat body without prying on it.
- Mark the mounting holes using the base as a template, then drill.
- Pull the wire bundle through the base and secure the sub-base. Leveling is for appearance only.
- Connect the wires to the base terminal block using the correct wiring diagram.
- Push excess wire into the wall and seal the hole with fire-resistant material to stop drafts.
- Remove the battery tag to engage the batteries.
Applies to: XR103 wall mounting
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR103 installation and user guide 18-HD55D1-1C-EN, p. 3-4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.