T on/T off aux heat control method

Daikin One Touch

What is going on

T on and T off let the main heat pump control the aux heat source using its PI algorithm. This is the only control option for AC-only outdoor units. If the indoor unit is a gas furnace or an air handler with a heater strip, that heat source is controlled around the heat setpoint by the demand-based algorithm, and the aux source is controlled independently.

Check in this order

  1. Choose T on/T off if the main heat pump should drive the aux heat.
  2. Use T on/T off as the only option with an AC-only outdoor unit.
  3. With a gas furnace or heater strip indoor unit, expect demand-based control around the heat setpoint.

Applies to: Aux heat control with heat pump, AC-only or gas furnace indoor units

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin One Touch smart thermostat training module TRC-10, p. 43. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.