Strapping the line set to the structure
What is going on
Support the line set so it does not rub or touch the structure.
Check in this order
- Vertical runs keep the lines off the wall. Use a sleeve through the wall and a strap or wire tie around the gas line, with the liquid line strapped to it.
- Horizontal runs strap the gas line to the joist or rafter every 8 ft using metal strapping or heavy nylon tie.
- After the gas line is strapped, strap the liquid line to the gas line.
- Strap only the gas line where it crosses the joist or rafter so the liquid line stays off the structure.
- Anchor all straps securely.
Applies to: Line set routing indoors and through walls
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin DX6VS/DZ6VS outdoor unit installation & service reference, p. 13. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.