Trane · Heat pump troubleshooting
SERVICE icon flashing on LCD
What is going on
The SERVICE icon on the display means the saved setup may be incomplete or was interrupted.
Likely causes
- Power was lost or removed within 5 seconds of saving setup choices.
Check in this order
- Press any key.
- Check every setup choice in installer and user setup.
- Re-enter any choice that is wrong and save again at step 99 (SA).
Applies to: TCONT402AN32DA Comfort Control
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR402 installer's guide 18-HD29D3-4, p. 3. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.